Phosphor bronze vs brass for terminals and contacts (C5191 vs C2680)

Brass (C2680, about 27 % IACS) costs less and conducts roughly twice as well, so it suits terminals that are crimped, soldered or press-fitted without a working spring. Phosphor bronze (C5191, 13 to 15 % IACS, up to 685 MPa) holds spring force and resists fatigue and stress relaxation far better, so choose it where the contact must keep pressing through many cycles or years of service.

Side-by-side data

C5191C2680
UNSC51900C26800
EquivalentsEN CuSn6 / CW452K; JIS C5191; GB QSn6.5-0.1EN CuZn33 / CW506L; JIS C2680; GB H65
Composition %Sn 5.5 – 7.0, P 0.03 – 0.35, Cu + Sn + P ≥ 99.5Cu 64.0 – 68.0, Pb ≤ 0.05, Fe ≤ 0.05
Conductivity %IACS13 – 15≈ 27
Tensile strength MPa315 – 685275 – 620
TempersO, 1/4H, 1/2H, H, EHO, 1/4H, 1/2H, H, EH
Elastic modulus110 GPa–
Density8.83 g/cm³8.47 g/cm³

Tensile strength is the range across supplied tempers. Full composition, tempers and physical properties are on each grade page.

Choose brass when

Choose phosphor bronze when

Notes

If the part needs both higher conductivity and spring force, look at a Corson alloy (C7025, C19010) or a copper-nickel-tin alloy (NB109, NB105) rather than compromising between brass and phosphor bronze.

Questions buyers ask

Why does phosphor bronze conduct less than brass?

Tin dissolved in the copper scatters electrons more strongly than zinc does, so even 6 % tin cuts conductivity more than about 33 % zinc.

Need a recommendation for a specific part?

Tell us the part function, strip thickness and performance targets. We reply within one working day, and sample coils are available for comparative trials.