C19010 vs C7025: lower or higher nickel Corson alloy
Both are copper-nickel-silicon (Corson) alloys. C19010 has less nickel, conducts 55 % IACS or more and reaches 360 to 590 MPa, so it suits terminals that carry more current and need moderate spring force. C7025 has more nickel and reaches 620 to 860 MPa at 40 % IACS or more, so it is the choice for fine-pitch connector terminals that need higher contact force.
Side-by-side data
| C19010 | C7025 | |
|---|---|---|
| UNS | C19010 | C70250 |
| Equivalents | EN CuNiSi (low-alloyed) | EN CuNi3SiMg; JIS C7025 |
| Composition % | Ni 0.8 – 1.8, Si 0.15 – 0.35, P 0.01 – 0.05 | Ni 2.2 – 4.2, Si 0.25 – 1.2, Mg 0.05 – 0.30 |
| Conductivity %IACS | ≥ 55 | ≥ 40 |
| Tensile strength MPa | 360 – 590 | 620 – 860 |
| Tempers | 1/4H, 1/2H, H, EH, SH | TM00, TM02, TM03 |
| Elastic modulus | 127 GPa | 131 GPa |
| Density | 8.9 g/cm³ | 8.82 g/cm³ |
Tensile strength is the range across supplied tempers. Full composition, tempers and physical properties are on each grade page.
Choose C19010 when
- The terminal carries significant current
- Moderate spring force is enough
- You are moving up from brass or phosphor bronze for conductivity
Choose C7025 when
- Contact force is the main requirement
- The terminal is fine-pitch or thin
- Resistance to stress relaxation at elevated temperature matters
Notes
For still higher strength in thin gauge, C7035 extends the Corson family; see the C7025 vs C7035 guide.
Questions buyers ask
Are C19010 and C7025 interchangeable?
Not directly. C7025 is considerably stronger, so a C19010 part redesigned in C7025 may be thinner, and a C7025 part moved to C19010 usually needs more thickness to keep contact force. Send the drawing and we will check.
Need a recommendation for a specific part?
Tell us the part function, strip thickness and performance targets. We reply within one working day, and sample coils are available for comparative trials.
Material development support