Bobon Copper

Guides

C1100 vs C1020: ETP copper or oxygen-free copper (T2 vs TU1)

Both conduct at about 100 % IACS, so the choice is about oxygen, not conductivity. C1100 (ETP copper, Cu ≥ 99.90 %) is the standard, more economical choice for busbars, shunts and stamped conductors that are joined mechanically or by soldering. Choose C1020 (oxygen-free, Cu ≥ 99.96 %, O ≤ 10 ppm) when the part will be brazed, welded or annealed in a hydrogen-bearing atmosphere, where the oxygen in ETP copper can cause embrittlement, or for vacuum and electronic devices.

Side-by-side data

C1100C1020
UNSC11000C10200
EquivalentsEN Cu-ETP / CW004A; JIS C1100; GB T2EN Cu-OF / CW008A; JIS C1020; GB TU1 / TU2
Composition %Cu (incl. Ag) ≥ 99.90Cu ≥ 99.96, O ≤ 10 ppm
Conductivity %IACS101≥ 100
Tensile strength MPa262 – 379195 – 315
TempersH01, H02, H04, H08O, 1/4H, 1/2H, H
Elastic modulus117 GPa117 GPa
Density8.91 g/cm³8.94 g/cm³

Tensile strength is the range across supplied tempers. Full composition, tempers and physical properties are on each grade page.

Choose C1100 when

Choose C1020 when

Notes

For the highest purity (Cu ≥ 99.99 %), C10100 (OFE) is the next step up; see the oxygen-free copper guide. Neither C1100 nor C1020 is a spring material: where a pure-copper part needs to hold its shape after heating, consider silver-bearing copper C10700.

Questions buyers ask

Is T2 the same as C1100?

They are the corresponding grades in the Chinese GB and the Japanese/US systems: GB T2, JIS C1100, UNS C11000 and EN Cu-ETP. Composition limits differ slightly between standards, so state which standard applies when ordering.

Is TU1 the same as C1020?

TU1 and TU2 are the GB oxygen-free coppers that correspond to JIS C1020, UNS C10200 and EN Cu-OF.

Need a recommendation for a specific part?

Tell us the part function, strip thickness and performance targets. We reply within one working day, and sample coils are available for comparative trials.

Material development support