Copper alloy selection for lead frames
C19400 is the standard lead frame alloy: at least 60 % IACS with moderate strength at an economical price. Use C7025 for thin, high-pin-count frames that need more strength, and C18140 for power devices where heat dissipation dominates.
Candidate grades
| C19400 | C7025 | C18140 | |
|---|---|---|---|
| UNS | C19400 | C70250 | C18140 |
| Equivalents | EN CuFe2P / CW107C; JIS C1940; GB QFe2.5 (TFe2.5) | EN CuNi3SiMg; JIS C7025 | EN CuCrZr (low-alloyed) |
| Composition % | Fe 2.1 – 2.6, P 0.015 – 0.15, Zn 0.05 – 0.20, Cu ≥ 97.0 | Ni 2.2 – 4.2, Si 0.25 – 1.2, Mg 0.05 – 0.30 | Cr 0.15 – 0.45, Zr 0.05 – 0.25, Si 0.005 – 0.05 |
| Conductivity %IACS | ≥ 60 | ≥ 40 | 85 |
| Tensile strength MPa | 365 – 550 | 620 – 860 | 393 – 490 |
| Tempers | 1/2H (H02), H (H04), EH (H06), SH (H08), ESH (H10) | TM00, TM02, TM03 | H04, H08 |
| Elastic modulus | 121 GPa | 131 GPa | 117 GPa |
| Density | 8.91 g/cm³ | 8.82 g/cm³ | 8.91 g/cm³ |
Tensile strength is the range across supplied tempers. Full composition, tempers and physical properties are on each grade page.
By package type
- Discrete and general IC packages: C19400
- Thin, fine-lead packages: C7025
- Power packages: C18140
Notes
Lead frame strip also has requirements for flatness, residual stress and surface condition for plating. Include them in the enquiry so the right material condition is quoted.
Questions buyers ask
Is C19400 suitable for etched lead frames?
It is used for both stamped and etched frames. For etching, state the flatness and residual-stress requirement in the enquiry.
Need a recommendation for a specific part?
Tell us the part function, strip thickness and performance targets. We reply within one working day, and sample coils are available for comparative trials.