Beryllium copper vs copper-titanium: choosing a high-strength spring alloy
Copper-titanium is the usual beryllium-free replacement for C17200 in small signal contacts and springs: it reaches 885 to 1,180 MPa with good bend formability. Stay with beryllium copper when the contact carries real current or needs the highest strength, because C17200 conducts two to three times better (22 to 28 % IACS against 8 to 13 %) and reaches about 1,500 MPa after age hardening.
Side-by-side data
| C17200 | C1990 | YCuT-FX | |
|---|---|---|---|
| UNS | C17200 | C19900 | C19900 |
| Equivalents | EN CuBe2 / CW101C; JIS C1720; GB QBe2 (TBe2) | JIS C1990; EN CuTi3 | JIS C1990 |
| Composition % | Be 1.80 – 2.00, Co + Ni ≥ 0.20, Co + Ni + Fe ≤ 0.60 | Ti 2.9 – 3.5 | Ti 3.2 |
| Conductivity %IACS | 22 – 28 | 8 – 13 | 13 |
| Tensile strength MPa | 410 – 1520 | 885 – 1180 | 985 – 1115 |
| Tempers | A (TB00), 1/4H (TD01), 1/2H (TD02), H (TD04), AT (TF00), 1/2HT (TH02), HT (TH04) | EH, SH, ESH | H, EH, SH, ESH |
| Elastic modulus | 131 GPa | 127 GPa | 125 GPa |
| Density | 8.25 g/cm³ | 8.70 g/cm³ | 8.7 g/cm³ |
Tensile strength is the range across supplied tempers. Full composition, tempers and physical properties are on each grade page.
Choose copper-titanium (C1990, YCuT-FX) when
- The customer or the end product requires beryllium-free material
- The contact carries signal-level current, so 8 to 13 % IACS is enough
- The spring is very thin and must hold force at temperature
Choose beryllium copper (C17200) when
- Current or heat dissipation matters and the higher conductivity is needed
- The part needs strength above about 1,200 MPa
- The part is formed soft and then age hardened to shape
Notes
YCuT-FX has the same basic composition as C1990 and is processed for a better balance of strength and bend formability in thin strip. Copper-titanium is supplied mill hardened. C17200 is available both mill hardened and in heat-treatable tempers.
Questions buyers ask
Is copper-titanium a drop-in replacement for beryllium copper?
Mechanically it is close in many spring designs, but the lower conductivity raises contact temperature under load. Check the current rating before switching.
Need a recommendation for a specific part?
Tell us the part function, strip thickness and performance targets. We reply within one working day, and sample coils are available for comparative trials.